Loosen outlet plugs in front of valve blocks. Fast purge the system with lubrication system purge gun until clean DNFT on Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.) 3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C … Read Here

CC Technology
Part# LPS for Lincoln & Part# DPS for Dropsa Divider Blocks. 2Year Warranty Reset Pressure Indicators The reset pressure indicator identifies tubing or lubrication point blockage to enable the operator to quickly verify exactly which point is causing high pressure in the system. … View Full Source

EN Divider Blocks
650150000093927_A User Instructions Divider Blocks Divider blocks are single line progressive hydraulic systems used to divide a single lubrication feed to multiple points while allowing each point to receive a different … Access Doc

CPI LUBRICATION Pump To Point Systems – Home – Compressor …
Part# DPS for Dropsa Divider Blocks. one piece O-Ring seal check valves with integral tube connection on base plate check valves All components are enclosed in the magnet assembly. Never lose a spring, spacer or magnet again. Springs tested to 20 million … View Document

Protecting Compressors Worldwide
Part# DPS for Dropsa Divider Blocks. one piece O-Ring seal check valves with integral tube connection on base plate check valves c d p totto a iff tot P All components are enclosed in the magnet assembly. Never lose a spring, spacer or magnet again. … Fetch Content

DIGITAL NO-FLOW TIMER WHITLOCK 2 1 4 0F To +1850F 3 7 3 0 8 1 …
Installation on dropsa/lincoln/sbco/lubriquip divider blocks. control housing polarized connector divider valve (e) caution: disconnect all wiring prior to welding on compressor or skid. wiring legend magnet (h) spacer spr ing #22 awg 18" leads (5) ( ) o-ring (f) 1/2“ pipe plug … Retrieve Document

1.800.337.3412 Www.noflo.com U.S. PAT. NO. 5,835,372 ODESSA …
On Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.) 3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C). Loosen outlet plugs in front of valve blocks. Fast purge the system with lubrication system purge gun until clean … Fetch This Document

1.800.337.3412 Www.noflo.com INSTRUMENT DNFT-LED-PS
On Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.) 3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C). Loosen outlet plugs in front of valve blocks. Fast purge the system with lubrication system purge gun until clean … Access Document

Proximity Switch With Captured Magnet Assembly
FOR ALEMITE, SB, TRABON/LUBRIQUIP, CPI TECH, LINCOLN, & DROPSA DIVIDER BLOCK SYSTEMS Proximity Switch with captured magnet assembly US Patent # 6,823,270 B1 with All Manufacturers Divider Blocks Ariel – SB – Graco/Trabon – Lincoln – DropsA … Doc Retrieval

Proflo PFI Having Packing, Rod Or Cylinder Wear Problems …
Dropsa Part #0-PF-DMA – ¼" BSP Lincoln Part #0-PF-LMA- w/ O-ring PROFLO INSTALLATION PROCEDURE FOR proflo MODEL PF1 1. a purge gun to purge air from the divider blocks and all components —– “BEFORE … Access Full Source

Compact Simple Mono-block Progressive divider Valve For One …
Progressive divider valve that is ideal for applications where space is limited. It is available in 6,8,10 and 12 outlet www.dropsa.com sales@dropsa.com ITALIA Dropsa SpA t. +39 02-250791 f.+39 02-25079767 U.K. Dropsa (UK) Ltd t. +44 (0)1784-431177 … Read Content

Made In USA
Part# LPS for Lincoln & Part# DPS for Dropsa Divider Blocks NeoMag Cycle Indicator: Visual Indication of the Divider Block Piston Movement to Monitor System Operation anad Oil Usage Part # NMT for: CCT, Graco/Trabon, Ariel, Lubriquip & SB Divider Blocks. … Retrieve Full Source

Protecting Compressors Worldwide – Home – Compressor Products …
Part# DPS for Dropsa Divider Blocks. HP divider blocks > Positive lubrication to cylinders/packing CPI-HP divider blocks give you the closest piston to valve tolerance in the world! 80 to 90 millionths-of-an-inch assures you precision lubrication of vital … Fetch Full Source

DNFT WHITLOCK 1300 N. Texas Odessa, TX 79761 1.800.337.3412 …
Loosen outlet plugs in front of valve blocks. Fast purge the system with lubrication system purge gun until clean DNFT on Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.) 3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C … Access Full Source

No-Flow Monitor 723LIT KENCO-NFM-1 Model NFM
Dr – proximity switch for dropsa divider blocks nfm ml. no-flow monitor wiring instructions model nfm *all trademark names are the property of their respective companies and are not associated with kenco limited. distributed by wiring diagram for open loop "or" closed loop operation blue … Retrieve Document

INSTRUMENT Switch Rating DC ODESSA, TX USA L C
Installation on dropsa/lincoln/sbco/lubriquip divider blocks. control housing polarized connector divider valve (e) caution: disconnect all wiring prior to welding on compressor or skid. wiring legend magnet (h) spacer spr ing #22 awg 18" leads (5) ( ) o-ring (f) 1/2“ pipe plug … Access Full Source

WARNING: WELDING ON THE COMPRESSOR SKID OR PIPING WITH THE …
Alemite, SB & Trabon Dropsa Lincoln 1. Loosen all Allen head set screws (2) (A) on top of proflo Jr. case and remove magnet housing (C). 2. NOTE: For Lincoln divider blocks it may be necessary to adjust the proflo Jr. by sliding the … Read Content

C2174PE Ultrasensor DM
Ultrasensor DM will work with standard DM divider blocks as a screw‐on accessory without requiring special www.dropsa.com sales@dropsa.com … Content Retrieval